Rubbertech would like to store cookies on your computer to customise our website performance and for analysis purposes. Cookies essential for the operation of the site content management system (Joomla) have already been set. To find out more about the cookies we use and how to delete them, see our privacy policy.

continue

Protect Technical Data

Protect – Technical Data
Application Protective sheeting for the building construction industry
Material Recycled rubber granulate bonded with a cold-cure PUR
Granulate Structure Coarse
Mass density kg/m³ - DIN EN ISO 845 730 kg/m³ ± 5%
Standard dimensions Rolls: 6mm = 10m Length; 8mm = 10m Length; 10mm = 6m Length
Sheets: Available upon request
Dimensional tolerance – DIN 7715-2 M4 ± 1.5 %
Testing thickness – DIN 53534 10 mm
Compression test according – DIN EN ISO 3386-2 CC25 = 539 kPa
CC40 = 1803 kPa
CC50 = 4660 kPa
Compression at 10% pressure – DIN 53421 0.24 MPa (E-Module) 2.9 MPa
Tensile strength – DIN EN ISO 1798 0.42 MPa (average)
Elongation at break – DIN EN ISO 1798 46 % (average)
Shore-A-hardness – DIN 53505 48-52 A
Thermal conductivity – DIN 52612 0.14 W/m K
Water vapour transmissions – DIN EN ISO 12572 µ14
Chemical resistance Resistant against acids and bases Conditionally resistant against oils
Temperature tolerance -40 to +110 ºC (for a limited time)
Fire classification – DIN 4102 B2
Date of Issue 01/2009 – (No update requirement)

 

Protect Plus – Technical Data
Application High density protective sheeting for building construction applications
Material Recycled rubber granulate bonded with a cold-cure PUR
Granulate Structure Coarse
Mass density kg/m³ - DIN EN ISO 845 930 kg/m³ ± 5%
Standard dimensions Rolls: width 1250 mm, length according to demand – upon request
Sheets: Width 1250 mm, length according to demand – upon request
Dimensional tolerance – DIN 7715-2 M4 ± 1.5 %
Material thickness  4 – 12 mm ± 0.3 mm
13 – 20 mm ± 1.0 mm
Testing thickness – DIN 53534  10 mm
Compression test according – DIN EN ISO 3386-2 CC25 = 1800 kPa
CC40 = 5400 kPa
Compression at 10% pressure – DIN 53421 0.82 MPa - 9.6 MPa (E-Module)
Tensile strength – DIN EN ISO 1798 >1.0 MPa
Elongation at break – DIN EN ISO 1798 70 % (average)
Shore-A-hardness – DIN 53505 55 A
Thermal conductivity – DIN 52612 0.14 W/m K
Chemical resistance Resistant against acids and bases. Conditionally resistant against oils
Temperature tolerance -40 to +110 º C
Fire classification – DIN 4102 B2
Date of Issue 04/2009 – (No update requirement)